Light source Infrared LED(855nm)
Effective aperture angle(EAA) Within ± 2.5 ° when the sensing distance is greater than 3 m for both emitter and receiver.
Sensing distance Short - Long mode (setting switch)
Short mode 0.2 to 5 m
Long mode 0.2 to 10 m
Detection capability Ø 14 mm (finger)
Sensing target Opaque
Protective height 792 mm
Number of optical axes 87
Optical axis pitch 9mm
Series connection Max. 3 SET (≤ 300 optical axes)
Power supply 24 VDC ±20 %(ripple P-P: ≤10 %)
Current consumption Emitter: ≤106mA, receiver: ≤181mA
Safety related output: OSSD output NPN or PNP open collector
Load voltage : ON - 24 VDC (except for the residual voltage), OFF - 0 VDC
Load current : ≤ 300 mA
Residual voltage : ≤ 2 VDC(except for voltage drop due to wiring)
Load capability: ≤ 2.2 ㎌
Leakage current: ≤ 2.0 mA
Wire resistance of load: ≤ 2.7 Ω
Auxiliary output(AUX 1/2) NPN or PNP open collector
Load voltage: ≤ 24 VDC, Load current: ≤ 100 mA,
Residual voltage: ≤ 2 VDC (except for voltage drop due to wiring)
Lamp output(LAMP 1/2) NPN or PNP open collector
Load voltage: ≤ 24 VDC, Load current: ≤ 300 mA
Protection circuit Reverse power polarity, reverse output polarity, output short-circuit over-current protection
Safety-related functions Interlock (reset hold), external device monitoring (EDM), muting/override, Blanking (fixed blanking, floating blanking), reduced resolution
General functions Self-test, alarm for reduction of incident light level, mutual interference prevention
Others functions Change of sensing distance, switching to NPN or PNP, external test (light emission stops), auxiliary output (AUX 1, 2), lamp output (LAMP1, 2)
Synchronization type Timing method by RS485 synchronous line
Insulation resistance Over 20MΩ (at 500VDC megger)
Noise immunity The square wave noise (pulse width: 1㎲) by the noise simulator ±240VDC
Dielectric strength 1,000VAC 50/60Hz for 1 minute
Vibration 10 mm double amplitude at frequency of 5 to 150 Hz, 10 sweeps ni each X, Y, Z direction
Shock 250 m/s² (≈ 25 G), pulse width 6 ms in each X, Y, Z direction for 100 times
Environment_Ambient illumination Sunlight: Max. 10,000lx, Incandescent lamp: Max. 3,000lx (received illumination)
Ambient temperature -30 to 60 ℃, storage: -30 ~ 70 ℃ (no freezing or condensation)
Ambient humidity 35 to 85 %RH, storage: 35 to 95 %RH (non-freezing or non-condensation)
Protection structure IP65, IP67(IEC Standard), IP67G (JEM Standard), IP69K (DIN Standard)
Material Case: Aluminum, Front cover and sensing part: Polymethyl methacrylate, End cap: polycarbonate, Power I/O cable and connector cable: polyurethane (PUR) or polyvinyl chloride (PVC), Y type connector cable: polyvinyl chloride (PVC), lamp output cable and series connector cable: polyurethane (PUR), Top / Bottom adjustable bracket and Top / Bottom bracket: SUS304, Side adjustable bracket and Side bracket: nickel plated Zn
International standards UL 508, CSA C22.2 No. 14, ISO 13849-1 (PL e, Cat. 4), ISO 13849-2 (PL e, Cat. 4), UL 61496-1 (Type 4, ESPE), UL 61496-2 (Type 4, AOPDs), IEC/EN 61496-1 (Type 4, ESPE), IEC/EN 61496-2 (Type 4, AOPDs), IEC/EN 61508-1~-7 (SIL 3), IEC/EN 62061 (SIL CL 3)
Light source Infrared LED(855nm)
Effective aperture angle(EAA) Within ± 2.5 ° when the sensing distance is greater than 3 m for both emitter and receiver.
Sensing distance Short - Long mode (setting switch)
Short mode 0.2 to 5 m
Long mode 0.2 to 10 m
Detection capability Ø 14 mm (finger)
Sensing target Opaque
Protective height 792 mm
Number of optical axes 87
Optical axis pitch 9mm
Series connection Max. 3 SET (≤ 300 optical axes)
Power supply 24 VDC ±20 %(ripple P-P: ≤10 %)
Current consumption Emitter: ≤106mA, receiver: ≤181mA
Safety related output: OSSD output NPN or PNP open collector
Load voltage : ON - 24 VDC (except for the residual voltage), OFF - 0 VDC
Load current : ≤ 300 mA
Residual voltage : ≤ 2 VDC(except for voltage drop due to wiring)
Load capability: ≤ 2.2 ㎌
Leakage current: ≤ 2.0 mA
Wire resistance of load: ≤ 2.7 Ω
Auxiliary output(AUX 1/2) NPN or PNP open collector
Load voltage: ≤ 24 VDC, Load current: ≤ 100 mA,
Residual voltage: ≤ 2 VDC (except for voltage drop due to wiring)
Lamp output(LAMP 1/2) NPN or PNP open collector
Load voltage: ≤ 24 VDC, Load current: ≤ 300 mA
Protection circuit Reverse power polarity, reverse output polarity, output short-circuit over-current protection
Safety-related functions Interlock (reset hold), external device monitoring (EDM), muting/override, Blanking (fixed blanking, floating blanking), reduced resolution
General functions Self-test, alarm for reduction of incident light level, mutual interference prevention
Others functions Change of sensing distance, switching to NPN or PNP, external test (light emission stops), auxiliary output (AUX 1, 2), lamp output (LAMP1, 2)
Synchronization type Timing method by RS485 synchronous line
Insulation resistance Over 20MΩ (at 500VDC megger)
Noise immunity The square wave noise (pulse width: 1㎲) by the noise simulator ±240VDC
Dielectric strength 1,000VAC 50/60Hz for 1 minute
Vibration 10 mm double amplitude at frequency of 5 to 150 Hz, 10 sweeps ni each X, Y, Z direction
Shock 250 m/s² (≈ 25 G), pulse width 6 ms in each X, Y, Z direction for 100 times
Environment_Ambient illumination Sunlight: Max. 10,000lx, Incandescent lamp: Max. 3,000lx (received illumination)
Ambient temperature -30 to 60 ℃, storage: -30 ~ 70 ℃ (no freezing or condensation)
Ambient humidity 35 to 85 %RH, storage: 35 to 95 %RH (non-freezing or non-condensation)
Protection structure IP65, IP67(IEC Standard), IP67G (JEM Standard), IP69K (DIN Standard)
Material Case: Aluminum, Front cover and sensing part: Polymethyl methacrylate, End cap: polycarbonate, Power I/O cable and connector cable: polyurethane (PUR) or polyvinyl chloride (PVC), Y type connector cable: polyvinyl chloride (PVC), lamp output cable and series connector cable: polyurethane (PUR), Top / Bottom adjustable bracket and Top / Bottom bracket: SUS304, Side adjustable bracket and Side bracket: nickel plated Zn
International standards UL 508, CSA C22.2 No. 14, ISO 13849-1 (PL e, Cat. 4), ISO 13849-2 (PL e, Cat. 4), UL 61496-1 (Type 4, ESPE), UL 61496-2 (Type 4, AOPDs), IEC/EN 61496-1 (Type 4, ESPE), IEC/EN 61496-2 (Type 4, AOPDs), IEC/EN 61508-1~-7 (SIL 3), IEC/EN 62061 (SIL CL 3)
4.9
12 views
Reviews
Reviews
Q How to make a payment?
E****R 18/11/2024
A We accept various payment methods including bank transfers, credit cards, and PayPal. Please refer to our payment page during checkout for detailed instructions on how to complete your payment. If you have any questions or need assistance with payment, please contact our customer support team.
18/11/2024
Q How will the products be shipped?
T****k 16/08/2024
A We ship products through reliable courier services such as DHL, UPS, and FedEx. Shipping fees and delivery times may vary depending on the destination. You will receive a tracking number once your order has been dispatched, allowing you to track the status of your shipment. Please note that shipping times may vary based on location and availability.
16/08/2024
Q How is warranty provided?
L****Y 08/05/2024
A We offer a warranty on all of our products. The warranty period and conditions vary depending on the product category. For specific warranty information, please refer to the product page or your purchase agreement. If you encounter any issues with a product during the warranty period, please contact our customer service team with your proof of purchase, and we will guide you through the warranty claim process.
08/05/2024
★ ★ ★ ★ ★ 16/08/2024
Good service!
(156)
★ ★ ★ ★ ★ 23/07/2024
Good!
(982)
★ ★ ★ ★ ★ 23/07/2024
Good quality!
(982)