PRCMT12-4DO
InstallationNon-flush
Sensing side diameterØ12mm
Sensing distance4mm
Hysteresis(distance)Max. 10% of sensing distance
Standard sensing target12×12×1mm(iron)
Response frequency500Hz
IndicatorOperation indicator (red LED)
Unit weight (packaged weight)≈ 26 g (≈ 38 g)
Power supply12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC
Current specificationLeakage current: Max. 0.6mA
Control output2 to 100 mA
Residual voltageMax. 3.5V
Protection circuitSurge protection circuit, output short over current protection circuit, reverse polarity protection circuit
Insulation resistance≥ 50 MΩ (500 VDC megger)
Dielectric strengthBetween the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min
Vibration1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours
Shock500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times
Environment_Ambient temperature-25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation)
Environment_Ambient humidity35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation)
Protection structureIP67(IEC standard)
ConnectionConnector models
Connector typeM12 Connector
MaterialCase/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
Sensing side diameterØ12mm
Sensing distance4mm
Hysteresis(distance)Max. 10% of sensing distance
Standard sensing target12×12×1mm(iron)
Response frequency500Hz
IndicatorOperation indicator (red LED)
Unit weight (packaged weight)≈ 26 g (≈ 38 g)
Power supply12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC
Current specificationLeakage current: Max. 0.6mA
Control output2 to 100 mA
Residual voltageMax. 3.5V
Protection circuitSurge protection circuit, output short over current protection circuit, reverse polarity protection circuit
Insulation resistance≥ 50 MΩ (500 VDC megger)
Dielectric strengthBetween the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min
Vibration1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours
Shock500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times
Environment_Ambient temperature-25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation)
Environment_Ambient humidity35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation)
Protection structureIP67(IEC standard)
ConnectionConnector models
Connector typeM12 Connector
MaterialCase/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
4.9
★ ★ ★ ★ ★
12 views
5 star 3 (100%)
4 star 0 (0%)
3 star 0 (0%)
2 star 0 (0%)
1 star 0 (0%)
Reviews
All Reviews(3) Image/Video(0) 5 star(3)
×
0/500
Score Excellent
★ ★ ★ ★ ★ 16/08/2024
Good service!
(156)
★ ★ ★ ★ ★ 23/07/2024
Good!
(982)
★ ★ ★ ★ ★ 23/07/2024
Good quality!
(982)